Keterangan:The TR125 can aid in the chemical digestion of samples that require it, such as in, the determination of COD, TOC, total phosphate and total nitrogen.

The required temperatures and reaction times are pre-programmed, and easy to select by using the keypad on the front of the reactor. It is also possible to pre-select reaction times of 30, 60 and 120 minutes as well as continuous operation. When digestion is complete, the reactor automatically switches off and sounds an alarm.

The Chemical Oxygen Demand ( COD) test is widely used as a measure of organic contamination by determing the quantity of oxygen required for oxidation of reduced species including organic matter, in a water sample using a specific oxidizing agent, temperature and time reduction.

COD testing is more reliable and is preferred to BOD testing as test results are more reproducible and are ready in two hours ( or less) rather than 5 days. In addition, COD testing is a better indicator of organic pollutants in industrial wastewater containing cyanides and heavy metals.

COD testing affords rapid response to changing conditions before critical problems develop. The TR125 COD reactor is fitted with 24 holes for 16 mm diameter vials.

Specifications
Housing Round metal block in epoxy covered housing, 24 holes 16 mm Ø
Front keypad Robust membrane keypad with 4 keys
Temperature settings 70 / 100 / 120 / 150 ° C
158 / 212 / 248 / 302° F
± 0.3 ° C
Timer 30, 60, and 120 minutes with continuous operation, automatic turn-off with alarm
Heating 400 Watts, electronically controlled, with overheating protection
Prep. time approx. 10 minutes
Power supply 230 V/ 115 V/ 50-60 Hz
Weight 7.9 pounds
Dimensions
( L x W x H) 10.83 x 6.10 x 3.74 inches
Approval CE, UL, TUV

Part Number Description
TR12500 TR125 Thermoreactor24 ( 16 mm) tube capacity
SC400-01S > > SC400 COD SetIncludes SC400 Colorimeter for COD Analysis, TR125 Reactor, Tube Test Rack, and 25 count packages of Low and Mid Range COD Reagents.
L418952 Test Tube Rack, 24 tube capacity, 16 mm ø



Korespondensi Perusahaan
Nama:Tn. Ernest Haliman [Penjualan]
E-mail:ernesthaliman@damarus.com
Nomer HP:08988847027
Nomer Telpon:62-21-63866340
Nomer Faks:62-21-6321080
Alamat:Jl kaji no 49/51 Jakarta Pusat
jakarta Pusat 10130, Jakarta
Indonesia
http: / / maps.google.co.id/ maps? q= jalan+ kaji+ no+ 49


Membuat situs langsung jadi?
Silahkan Klik disini!